Specification of PLC Splitter
Implementation of standards
1.1 Bellcore GR1209-CORE
1.2 Bellcore GR1221-CORE
1.3 YD-T 2000.1-2014
Parameter: 1×N PLC splitter
Parameter |
1×2 |
1×4 |
1×8 |
1×16 |
1×32 |
1×64 |
1×128 |
|||
wavelength(nm) |
1260~1650 |
|||||||||
Fiber type |
G657A1 |
|||||||||
With connect Insertion Loss (dB) |
4.1/4.4 |
7.4/7.9 |
10.5/11 |
13.8/14.1 |
17.1/17.4 |
19.8/21 |
24.0/24.7 |
|||
Without connect insertion Loss(dB) |
3.8/4.1 |
7.1/7.6 |
10.2/10.7 |
13.5/13.8 |
16.8/17.1 |
20.1/20.7 |
24.1/24.6 |
|||
Uniformity of the insertion loss (dB) |
0.6 |
0.7 |
0.8 |
1.0 |
1.5 |
2.0 |
2.0 |
|||
PDL(dB) |
0.1 |
0.1 |
0.1 |
0.20 |
0.25 |
0.25 |
0.3 |
|||
Return Loss (dB) |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|||
Directivity (dB) |
55 |
55 |
55 |
55 |
55 |
55 |
55 |
|||
Wavelength loss uniformity (dB) |
0.3 |
0.3 |
0.3 |
0.3 |
0.5 |
0.5 |
0.5 |
|||
Temperature sensibility (-40~85 ℃)(dB) |
0.4 |
0.4 |
0.4 |
0.5 |
0.5 |
0.5 |
0.5 |
|||
Operating Temperature (℃) |
-40~80 |
|||||||||
Storage Temperature (℃) |
-40~85 |
|||||||||
ABS Module size (mm) |
100×80×10 |
120×80×18 |
141×115×18 |
|||||||
MINI Module size (mm) |
40×4×4 |
60×7×4 |
60×7×4 |
60×12×4 |
80×20×6 |
100×40×6 |
N/A |
- The above parameters are measured under normal temperature, and no contains the data of connectors.
- The parameter of including connectors should be added 0.1dB base on the above data.
Return Loss≥55dB(APC),≥50dB(UPC)。
Materials meet the following hazardous substances management requirements, flame retardant, high and low temperature
Control components |
Standard allowable content(ppm) |
Internal control content(ppm) |
Pb |
≤1000ppm |
≤200ppm |
Hg |
≤1000ppm |
≤200ppm |
Cd |
≤100ppm |
≤50ppm |
Dibromobiphenyl(PBB) |
≤1000ppm |
Total bromine content ≤400ppm |
Dibromodiphenyl ether(PBDE) |
≤1000ppm |
|
Operating temperature |
-40℃~+65℃ |
|
Flame retardant situation |
Flammability rating:UL94V-0 |
Product reliability requirements
Environmental life
No. |
Test Name |
Experiment method |
Judgement standard |
|
IL changes |
After the test shape changes |
|||
a |
High temperature storage(dry) |
85 ℃ (± 2 ℃) or the maximum storage temperature, humidity < |
≤0.5 |
Appearance without mechanical damage, such as deformation,Cracks, relaxation, etc., shall not appear Fiber break, cable pull out, light Failure at the end of the fiber and cable Seal damage and so on. |
b |
Low storage |
-40 ℃ (± 5 ℃) or the minimum storage temperature, duration of 2000h |
≤0.5 |
|
High temperature storage (heat) |
(± 5 ° C), 90% (± 5%) RH or 85 ° C (± 2 ° C), 85% (± 5%) RH, duration 500h (COa), 2000h (UNCb) |
≤0.5 |
||
c |
Temperature cycle |
(-40 ℃ ~ +85 ℃), a cycle of 8h, 500 cycles |
≤0.5 |
Mechanical reliability
No. |
Test Name |
Experiment method |
Judgement standard |
|
IL changes |
After the test shape changes |
|||
a |
Drop test |
Height: 1.8 m; |
≤0.5 |
Appearance without mechanical damage, such as deformation, cracks, relaxation, etc., shall not be broken fiber, cable pulled out, the end of the fiber failure and cable seal damage. |
b |
Vibration test |
Frequency: 10 ~ 55HZ; sweep frequency: 45 times per minute; |
≤0.5 |
Related Products
Contact Us
TEl: +86-13375459819
Email: Info@ytdq.con.cn
Whatsapp: 13375459819
Wechat: 13375459819
Contacter: Linda
Address:No 132,Beida street, Zhifu district, Yantai city, Shandong province, China
Yantai Yatai Photoelectricity Equipment Co.,Ltd.
Copyright © 2020 Yantai Yatai Photoelectricity Equipment CO.,LTD. All rights reserved 鲁ICP备11034121号-3 Powered by www.300.cn